  universal ac input / full range built-in active pfc function, pf 0.94 high efficiency up to 86% protections: short circuit / overload / over voltage / over temperature conformal coated years warranty cooling by free air convection1u low profile 36mm zvs technology to reduce power dissipation led indicator for power on 3 specification HDP-190 model output voltage range note.5 frequency range power factor (typ.) efficiency (typ.) input environment inrush current (typ.) leakage current over temperature safety standards safety & emc (note 4) withstand voltage isolation resistance working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage protection ac current (typ.) +3.8v +2.8v 33a 20a 0 ~ 40a 0 ~ 22a 181.4w (typ.) 192w (max.) 100mvp-p 100mvp-p 3.6 ~ 4v 2.5 ~ 3v 2.0% 2.0% 0.5% 0.5% 2.0% 2.0% 1000ms, 50ms/230vac 2500ms, 50ms/115vac at full load 16ms/230vac 16ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf 0.94/230vac pf 0.98/115vac at full load 2.7a/115vac 1.1a/230vac 30a/115vac 45a/230vac <2ma / 240vac v1: 4.37 ~ 5.13v protection type : shut down o/p voltage, re-power on to recover protection type : shut down o/p voltage, re-power on to recovery ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b, en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, en55024, en61000-6- 2, heavy industry level, criteria a i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh -30 ~ +70 (refer to "derating curve") 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes 111.3k hrs min. mil-hdbk-217f (25 ) 215*115*36mm (l*w*h) features : 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. 6. output voltage between v1 and v2 should be higher than 0.8v(v1-v2 0.8v) . h d p - 1 9 0 190w dual output with pfc function 0.95kg; 15pcs/15.3kg/0.7cuft 86% 95 5 (tsw1) detect on heatsink of power transistor file name:HDP-190-spec 2011-12-28 v1 v2 output number dc voltage rated current current range (max.) rated power voltage adj. range note.6 line regulation load regulation setup, rise time hold up time (typ.) ripple & noise (max.) note.2 voltage tolerance note.3 emc immunity emc emission 192w continue. v1 total power output shall not exceed 160w (max. 40a) ; v2 tota l power output shall not exceed 66w (max. 22a) (the v1 & v2 combine total power output shall not exceed 192w) output power (max.) v2: 3.22 ~ 3.78v v1+v2: 105 ~ 150% max. output power ; or v2: 125 ~ 170% rated current protection type: hiccup mode, recovers automatically after fault c ondition is removed
ambient temperature ( ) load (%) -30 0 10 20 30 40 50 60 70 (horizontal) mechanical specification pfc fosc : 65khz pwm fosc : 80khz 16max. 32.5 150 215 4-m4 l=5mm 1 2 3 4 5 6 7 8 9 10 11 15 15.85 svr1 svr2 led 24 32.5 150 115 108 44.75 34.4 32.5 10 50 95 97.5 204.5 215 5-m3 l=3mm 4-m4 l=5mm 12.5 36 135 8.3 9.5 3.5 16 o.l.p. o.v.p. terminal pin no. assignment : pin no. pin no. 1 4,5 3 svr1: v1(+3.8v)adj. svr2: v2(+2.8v)adj. 2 6,7 assignment assignment ac/l v2(+2.8v) fg ac/n v1(+3.8v) com 8,9,10,11 file name:HDP-190-spec 2011-12-28 derating curve output derating vs input voltage input voltage (v) 60hz 90 95 100 115 130 145 165 185 205 225 245 264 100 90 80 70 60 50 40 load(%) block diagram o.l.p. o.t.p. emi inrush active filter current limiting rectifiers & pfc i/p fg pwm pfc circuit detection power switching filter & rectifiers +v1 control control o.v.p. com +v2 h d p - 1 9 0 20 40 50 60 80 100 case no.206a unit:mm 190w dual output with pfc function filter & rectifiers circuit control detection pwm


▲Up To Search▲   

 
Price & Availability of HDP-190

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X